Calibration

Measure Tape Hiss Relative to a Recorded Signal

Compare a recorded tone and recorded silence with fixed gain.

Choose the tone, bandwidth and weighting

Use a blank cassette, a stereo line interface and REW’s live RTA for level readings. This procedure reads the deck directly; a separate WAV capture is optional evidence. Connect interface output → deck LINE IN and LINE OUT → interface line input. Disable automatic gain, NR and processing. Keep source, deck and capture controls fixed.

Generate a short 1 kHz sine at a moderate documented deck level. Follow it with at least ten seconds of digital silence while the deck remains in REC. This records the actual erase/bias/recording noise. An untouched blank or the deck in Stop is a different condition.

Record tone and silence at fixed gain

  1. Record the tone and silence on the cassette, then stop and rewind before the tone. Leave the deck stopped while preparing REW.
  2. Select one input channel in REW and open RTA. Use a dBFS display. Start the analyzer with its record control; observe the Input RMS reading, which represents average signal energy rather than instantaneous peaks.
  3. Press PLAY on the deck. Read the stable middle of the reference tone. Record the unweighted RMS value and the analysis bandwidth/filter settings.
  4. Read the middle of the recorded silence with the same channel, gain, bandwidth and unweighted RMS convention. Avoid the switching transient between tone and silence.
  5. Subtract noise level from signal level. Repeat for the other channel and another silence interval.
  6. If you also use A-weighting, record the corresponding A-weighted reference and noise values as a separate result. Weighting changes which frequencies count; do not mix weighted and unweighted numbers.

Select stable windows and work through the ratio

Hypothetical readings: tone −18 dBFS RMS, noise −70 dBFS RMS. The separation is 52 dB under those settings. It is not automatically comparable with a specification referenced to maximum output level or using a different weighting.

NAK T-100 offers Noise-A, but its scale offsets require attention. Use the NAK guide rather than treating its displayed noise scale as a ready-made positive SNR.

Choose windows long enough to avoid basing the result on one brief defect. Check whether the measured floor includes a periodic hum or a dropout. Keep the full capture so you can analyze another window without changing the original signal.

Report the result with the measurement conditions

If noise changes when the computer display or a charger switches, investigate electrical interference. If the “silence” contains music, confirm it was recorded over completely. If input gain changed between sections, repeat both readings. If you also save a WAV, preserve both sections in one unprocessed file without normalization.

Checklist: recorded silence, stated signal reference, identical gain, matching RMS/weighting/bandwidth and both channels. Test Dolby B as a separate matched encode/decode condition; switching only playback NR changes the question.

Write the tape type, noise reduction, test signal, bandwidth, weighting and gain beside the number. Report unusual noise separately if it affects the reading. Repeat the comparison after any change in recording or capture settings.

Frequently asked questions

Does the noise in Pause represent tape hiss?

Pause can change what the deck routes to its outputs, and it does not represent a quiet section moving past the playback head. Record a silent section at the same settings as the reference tone, then play it back normally for the comparison.

Can I compare weighted and unweighted SNR?

Different weightings give different importance to parts of the spectrum. Use the same bandwidth and weighting for a direct comparison. If you report both, label each clearly and use the same recorded reference, capture gain and time windows where the methods allow it.

How do I check for hum or dropouts?

Listen to the noise section and inspect the spectrum or waveform. A periodic hum and short dropouts can affect a reading differently from steady hiss. Choose a representative window for the measurement, then describe the other defects separately so the number has a clear meaning.

What changes if Dolby is active?

Encoding and decoding can change both the signal and the measured noise. Use the intended playback mode for the recording and document it. If you compare Dolby on and off, record separate samples with the relevant encoding and keep the other measurement conditions fixed.